1Operator’s ManualAutomotive AnalyzerIt’s More than a Multimeter
10Lo AmpsWhen the test is first selected the message “PLUG In LO” will be briefly displayed to remind the user that the Low range Amps p
11Volts • AmpsPressing the button will cycle you through the Volts•Amps Display and a Battery/Starter Test. The High range amp probe is used
12TimePress the Time button to cycle through Hertz, Pulse Width (Up Slope), Pulse Width (Down Slope), Dwell milliseconds, and Dwell percent tes
13Fuel TestThe Black amps probe will need to be connected to the wire that supplies battery power to the fuel pump. Energize the pump
14Coil TestPress this button to cycle through two Current Ramping tests (Peak Amps, Build Time, Drive Time), Ignition KV, and Differentia
15Coil Test - KV Test (Requires Optional Adapter)1. Unplug the Spark Pickup from the multimeter. 2. Connect the KV adapter to the multimeter. 3.
16Coil Test - Fuel Injector ApplicationPeak Amps is the peak current driving the injector. It is regulated by the driver. Typical peak readings ar
17Coil Test - Ignition Coil ApplicationPeak Amps is the peak current driving the coil. It is regulated by the module. A typical Peak Amp reading sh
18Parts & AccessoriesTest Lead, P/N W090-926 foot Shielded Test lead. BNC connector at one end, and banana jacks at the other end.Lo Amps Probe,
19Parts & AccessoriesSerial Lead, P/N V095-PCPlugs into the Amps jack on the meter and provides a Y adapter so you can connect your amps pro
2Table of ContentsSpecifications ...3Static Discharge Notice ...
20WarrantyFERRET BRAND LIMITED PRODUCT WARRANTYGxT, Inc. of Cheboygan Michigan, warrants to the original purchaser that FERRET brand products are free
21SAFETY PRECAUTIONS—Read All Instructions Before Using The Meter—• Always wear eye protection when testing vehicles. Be extra careful near batteries
22Notes
24Copyright © 2006 GxT, Inc. Cheboygan Michigan, USAE095-01
3SpecificationsDC Volts ...3 Ranges ... 1 mV to 50VAC Volts (True RMS) ...3 Ranges ...
4Battery Replacement / Optional BatteryWhen the LOBAT indicator comes on the display, you will need to replace the two 9 Volt batteries. Remove the 4
5Function ButtonsPress this button to turn the multimeter on and off.Press this button to set configure the RPM to read in 2 Cycle or 4 Cycle mode. Di
6Key Combinations & Special FunctionsBacklight ControlPress the HOLD button and the Min/Max button at the same time to turn the backlight
7VoltsPressing the button will cycle you through DC Volts, AC volts, and AC Peak to Peak functions. The bargraph is an easy way to
8989LOBATMAXMINΩHOLDContinuity DisplayOhmsThe highest Ohms range allows up to 40M Ohms to be measured. All of the ranges except the lowest u
9AmpsWhen the test is first selected the message “PLUG In HI” will be briefly displayed to remind the user that the High range Amps p
Commenti su questo manuale